CONTEC Portable Ambulatory Blood Pressure Monitor AMPM SPO2 NIBP/+Cuff+Probe NEW PC Software

$143.20$149.00

  • 1 Year AL Jazeera Brand Warranty
  • 30 Day Return Policy
  • Cash on Delivery available
Clear
Compare
SKU: 0QJM3OGY1VFQ Category:

Description

CONTEC Portable Blood Pressure NIBP/Spo2 +Cuff+Probe NEW PM50

Description
The Machine is a multifunctional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health care.
Major Features
1.Compact and portable, easy to use
2.With Integrative SpO2 Probe
3.Double working modes,monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set
4.NIBP and SpO2 can be monitored for a long time
5.NIBP and SpO2 data record for large capacity
6.With friendly user interface, the user can see list menu and review measure results
7.The device can display low power information, alarm information, error information and time information richly
8.Parameter alarm function is optional
9.Patient information can be flexibly set
10.Case management function.PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions
Main performance
1.NIBP
Measure Method: Oscillometry
Measure Mode: The upper arm measure
Measure range:
ADULT: SYS: 40mmHg~270mmHg
MAP:20mmHg~235mmHg
DIA: 10mmHg~215mmHg
PEDIATRIC: SYS: 40mmHg~200mmHg
MAP: 20mmHg~165mmHg
DIA: 10mmHg~150mmHg
NEONATAL: SYS: 40mmHg~135mmHg
MAP: 20mmHg~110mmHg
DIA: 10mmHg~100mmHg
Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes
Resolution: 1mmHg
Accuracy: ±3mmHg
Increasing pressure mode: force pump increases pressure automatically
Reducing pressure mode: self-motion ladder reducing pressure mode
Alarm parameter: SYS / MAP / DIA
2.SPO2
Measure range: 0%~100% (Resolution:1%)
Accuracy: 70-100%, ±2%, below 70% unspecified
Error in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
3.Pulse Rate
Measuring range:0bpm~250bpm
Resolution:1bpm
Accuracy: ±2 bpm or ±2% (select larger)
4.Display: 2.4″ TFT colour LCD
5.Power: DC 3V(Two “AA”,1.5V Alkali Battery)
6.Product safety type:Type BF applied part (Internally powered,defibrillation-proof)
Accessories
Cuff for adult.
Integrative SpO2 Probe
USB data line
Pack
User manual
Physical Identity
Dimension: 128mm*69mm*36 mm (No including Packing)
Weight: Software function
1.Up to 1000 patient cases can be edited and supervised.
2.The time segment of dealing with the patient’s NIBP data is 48 hours.
3.Connect the device by USB interface.
4.Can upload patient information data collection project and download collection data.
5.Can display scoop-shape trend graph,filling-type trend graph, histogram, pie chart, correlation line graph.
6.Can edit every piece of data, and add annotation to it.
7.Can edit basic information,doctor’s advice information, NIBP and SpO2 status instruction, current medicine-taken information, etc. Support print preview, print the report.

Additional information

Brand Name

Contec

Origin

China Mainland

Item Type

Blood Pressure

Certification

CE

Application

ARM

Reviews

There are no reviews yet.

Be the first to review “CONTEC Portable Ambulatory Blood Pressure Monitor AMPM SPO2 NIBP/+Cuff+Probe NEW PC Software”

Your email address will not be published. Required fields are marked *

Subscribe Our Newsletter